Scope of Accreditation

Laboratory Name: WearCheck Canada Inc

Client ID: 1005019

Parent Institution:

Address: WearCheck Canada Inc, C8-1175 Appleby Line, Burlington, Ontario, L7L 5H9

Contact: Bill Quesnel

Email: bill.quesnel@wearcheck.com

Phone: (905) 569-8600

Fax: (905) 569-8605

Standard: Conforms with requirements of ISO/IEC 17025:2017

Clients Served: All Interested Parties

Revised On: 05/16/2025

Valid To: 11/16/2027

CALA is committed to Canada's anti-spam legislation (CASL). Please note that the email addresses published on this website are provided solely for professional or informational purposes. Any use of these addresses for unsolicited commercial electronic messages or the harvesting of email addresses is strictly prohibited and may be subject to legal action under CASL.

001 - Kinematic Viscosity

Field of Accreditation: Petroleum

Matrix: Oil [Diesel, Lubricant]

Analytical Method: VISCOMETER

Preparation Method:

Lab Method ID(s): LWI002

Method Reference Modified From Analytical Method Preparation Method
ASTM D7279 Yes Yes No
Parameter
Viscosity at 100 degrees C
Viscosity at 40 degrees C

002 - Metals

Field of Accreditation: Petroleum

Matrix: Oil [Diesel, Lubricant]

Analytical Method: ICP

Preparation Method:

Lab Method ID(s): LWI101

Method Reference Modified From Analytical Method Preparation Method
ASTM D5185 Yes Yes No
Parameter
Aluminum
Barium
Boron
Calcium
Chromium
Copper
Iron
Lead
Magnesium
Manganese
Molybdenum
Nickel
Phosphorus
Potassium
Silicon
Silver
Sodium
Sulphur
Tin
Titanium
Vanadium
Zinc

003 - Water Content

Field of Accreditation: Petroleum

Matrix: Oil [Diesel, Lubricant]

Analytical Method: KARL FISCHER TITRATION

Preparation Method:

Lab Method ID(s): LWI021

Method Reference Modified From Analytical Method Preparation Method
ASTM D6304 No Yes No
Parameter
Water Content

004 - Particle Count

Field of Accreditation: Petroleum

Matrix: Oil [Diesel, Lubricant]

Analytical Method: PARTICLE COUNTER

Preparation Method:

Lab Method ID(s): LWI003

Method Reference Modified From Analytical Method Preparation Method
ASTM D7647 No Yes No
Parameter
Particle Count

005 - Oxidation Stability

Field of Accreditation: Petroleum

Matrix: Oil [Turbine]

Analytical Method: ROTATING PRESSURE VESSEL OXIDATION TEST (RPVOT)

Preparation Method:

Lab Method ID(s): LWI032

Method Reference Modified From Analytical Method Preparation Method
ASTM D2272 Yes Yes No
Parameter
Oxidation Stability

006 - Foaming Characteristics

Field of Accreditation: Petroleum

Matrix: Oil [Lubricant]

Analytical Method: GAS DIFFUSER STONES

Preparation Method:

Lab Method ID(s): LWI104

Method Reference Modified From Analytical Method Preparation Method
ASTM D892 No Yes No
Parameter
Foaming Characteristics – Sequence I (24C)
Foaming Characteristics – Sequence II (93.5)
Foaming Characteristics – Sequence III (43.5)

007 - Air Release

Field of Accreditation: Petroleum

Matrix: Oil [Hydrocarbon Based]

Analytical Method: AIR RELEASE VALUE APPARATUS

Preparation Method:

Lab Method ID(s): LWI106

Method Reference Modified From Analytical Method Preparation Method
ASTM D3427 No Yes No
Parameter
Air Release

008 - Acid Number

Field of Accreditation: Petroleum

Matrix: Oil

Analytical Method: TITRIMETRIC

Preparation Method:

Lab Method ID(s): LWI117, LWI028

Method Reference Modified From Analytical Method Preparation Method
ASTM D974 No Yes No
Parameter
Acid Number

009 - Rust Prevention

Field of Accreditation: Petroleum

Matrix: Oil

Analytical Method: VISUAL EXAMINATION

Preparation Method:

Lab Method ID(s): LWI108

Method Reference Modified From Analytical Method Preparation Method
ASTM D665 No Yes No
Parameter
Rust Prevention

010 - Water Separability

Field of Accreditation: Petroleum

Matrix: Oil

Analytical Method: VISUAL EXAMINATION

Preparation Method:

Lab Method ID(s): LWI107

Method Reference Modified From Analytical Method Preparation Method
ASTM D1401 No Yes No
Parameter
Water Separability

† “OSDWA” indicates the appendix is used for the analysis of Ontario drinking water samples, which is subject to the rules and related regulations under the Ontario “Safe Drinking Water Act” (2002).

The list of tests and measurement capabilities for which a laboratory is accredited can change at any time due to circumstances such as scope extensions, voluntary withdrawal of tests by the laboratory and suspension. Scopes are published by the CALA via the Internet at https://directory.cala.ca/